Fresh Air & Ventilation Systems

Ensuring continuous, filtered outdoor air exchanges for healthy, energy-efficient indoor environments across commercial, residential, and institutional facilities.

Fresh air ventilation handling unit with energy recovery wheel
Filtered Fresh Air

PM2.5 & CO₂ Control

Up to 80% Energy Recovery

ASHRAE 62.1 Aligned

Fresh Air System and Indoor Air Quality Engineering Diagram
Indoor Air Quality Fresh Air Advisory
Fresh Air & IAQ Advisory

Continuous Outdoor Air Exchange for Healthy Buildings

Fresh Air Systems ensure a continuous supply of filtered outdoor air to maintain healthy indoor environments. Sustainergic Tech designs ventilation systems that improve indoor air quality, control humidity, and comply with applicable ventilation standards while enhancing occupant health and comfort.

Dedicated Outdoor Air Systems (DOAS)

Decoupling latent humidity loads by supplying 100% pre-conditioned, dehumidified outdoor air.

Energy & Heat Recovery (ERV / HRV)

Capturing up to 80% of sensible and latent energy from exhaust air to pre-cool incoming fresh air.

Multi-Stage Air Filtration

Deploying MERV 13 to HEPA filtration to eliminate PM2.5, airborne allergens, bacteria, and VOCs.

Demand-Controlled Ventilation (DCV)

Automating fresh air CFM flow rates in real-time using indoor CO₂ sensor feedback.

Low CO₂ & VOC Levels
80% Enthalpy Heat Recovery
ASHRAE 62.1 Compliant
Ventilation Systems

Customized Fresh Air & IAQ Solutions

DOAS (Dedicated Outdoor Air Systems)

Specialized air handling units that condition 100% outdoor fresh air independently of internal space cooling. Handles 100% of the building's moisture/latent load, ensuring dry, comfortable indoor air.

Energy Recovery Ventilators (ERV / HRV)

High-efficiency enthalpy wheels and counter-flow heat exchangers that transfer thermal heat and moisture between exhaust air and fresh intake air, reducing cooling plant load by up to 30%.

Demand-Controlled Ventilation (DCV)

Smart ventilation damper controls linked to room CO₂ sensors. Automatically ramps up fresh air during high occupancy (meetings/events) and throttles back during low occupancy to save energy.

Positive Pressure Filtration Systems

Maintains positive indoor static pressure to block raw outdoor smog, ambient dust, and unconditioned hot air from infiltrating through doors, windows, and facade gaps.

IAQ & Health Impact

Why Fresh Air Systems Are Essential

Cognitive Boost & Wellness

Keeping indoor CO₂ levels under 800 ppm prevents drowsiness, headaches, and fatigue, boosting occupant productivity and mental focus by up to 15%.

Humidity & Mold Control

Pre-dehumidifying incoming outdoor air eliminates dampness, preventing mold, mildew, and fungal growth inside ductwork and wall cavities.

80% Enthalpy Energy Savings

Rotary enthalpy wheels pre-cool hot summer air using cool exhaust air, drastically reducing chiller capacity requirements and operating power.

Green Building certification Mandatory Points

Fulfills mandatory minimum ventilation prerequisites and earns valuable Indoor Environmental Quality (EQ) credit points for green building ratings.

Our Process

A 4-Step Fresh Air Engineering Roadmap

01

Fresh Air Load Calculation

Determining outdoor air CFM rates based on space usage, occupant density, and ASHRAE 62.1 / NBC guidelines.

02

System Selection & Ductwork Engineering

Selecting enthalpy heat recovery wheels, sizing low-friction duct routes, and specifying MERV 13/HEPA filter banks.

03

Controls & Sensor Integration

Integrating CO₂ monitors, humidity sensors, motorized dampers, and BMS VFD controls for demand-based regulation.

04

TAB & Air Quality Verification

Conducting Testing, Adjusting & Balancing (TAB) to measure exact air CFM, filter static pressure drops, and room pressure.

Ready to Enhance Indoor Air Quality for Your Building?

Partner with Sustainergic Tech to design, engineer, and commission high-performance fresh air and energy recovery ventilation systems.

Call +91 97857 49960